| The following organizations
publish standards, specifications and guidelines for performing
infrared inspections and/or related testing. |
| |
|
|
| American Society
for Testing and Materials |
| |
100 Barr Harbor Drive
West Conshocken, PA 19428 |
Telephone:
Fax:
Website: |
610.832.9585.
610.832.9555
www.astm.org
|
| |
- C 1060 Thermographic Inspection
of Insulation Installations in Envelope Cavities of
Frame Buildings
- C 1153 Standard Practice
for the Location of Wet Insulation in Roofing Systems
Using Infrared Imaging
- D 4788 Standard Test Method
for Detecting Delaminations in Bridge Decks Using
Infrared Thermography
- E 1186 Standard Practice
for Air Leakage Site Detection in Building Envelopes
and Air Retarder Systems
- E 1934 Standard Guide for
Examining Electrical and Mechanical Equipment with
Infrared Thermography
|
| ANSI |
| |
11 West 42nd Street
New York, NY 10006 |
Telephone:
Fax:
|
212.642.4900
212.302.1286 |
| |
- ISO
6781 Thermal Insulation - Qualitative Detection
of Thermal Irregularities in Building Envelopes -
Infrared Metho
|
| Danish Technology
Institute |
| |
Department of Energy Technology
Grefersensvej
P. O. Box 141
DK-2630
Taastrup, Denmark |
Telephone:
Fax:
|
45.43.50.45.00
45.43.50.72.22
|
| |
- TTCTRAN.015 Guideline for
Thermographic Inspection in Electrical Installations
|
| Infraspection Institute |
| |
425 Ellis Street
Burlington, NJ 08016 |
Telephone:
Fax:
Website: |
609.239.4788
609.239.4766
www.infraspection.com
|
| |
|
| InterNational Electrical
Testing Association |
| |
P. O. Box 687
106 Stone Street
Morrison, CO 80465-0687 |
Telephone:
Fax:
Website: |
303.697.8441
303.697.8431
www.netaworld.org
|
| |
- NETA MTS-2001 Maintenance
Testing Specification for Electrical Power Distribution
Equipment and Systems
- NETA ATS-1999 Acceptance
Testing Specification for Electrical Power Distribution
Equipment and Systems
|
| International Organization
for Standardization |
| |
Case Postale 56
CH-1211
Geneva, Switzerland |
Website: |
www.iso.org |
| |
ISO Documents
are available from ANSI please see their listing above.
|
| |
|
|
| National Fire Protection
Association |
| |
1 Batterymarch Park
P. O. Box 9101
Quincy, MA 02269 |
Telephone:
Website: |
800.344.3555
www.nfpa.org
|
| |
- NFPA 70B Recommended
Practice for Electrical Equipment Maintenance
- NFPA 79 Electrical
Standard for Industrial Machinery
|
| Roof Consultants
Institute |
| |
7424 Chapel Hill Road
Raleigh, NC 27607 |
Telephone:
Fax:
Website: |
919.859.0742
919.859.1328
www.rci-online.org
|
| |
|
|
| United States Navy |
| |
- MIL-STD-2194
Military Standard Infrared Thermal Imaging Survey
Procedure for Electrical Equipment
This
document is no longer circulated;
however, many thermographers continue to utilize it.
|