| February
2004 - Intruders can't hide and remote equipment inspections
are made easier with Mikron Infrared's new DualVision
724 Remote Monitoring System. Ideal for pump stations,
pipelines, telecom/broadcast facilities, electrical substations,
coal piles, and similar facilities, the system is the
first to combine visual and infrared cameras to produce
optimized, blended images for simple quick analysis -
all in a single intranet/internet-enabled package.
Utilized
with Mikron's MikroSpec R/T software, the system
produces a composite IR and visual image, as well as
separate images of each. The resulting composite can
be viewed in an infinitely blended percentage of visual/IR,
simply by moving a slider bar in the software screen.
Up to 32 regions
of interest (ROI's) can be defined on the thermal image
in any complex shape, enabling the
system to trigger alarms at the approach of intruders
or from temperature excursions on equipment. Visual
surveillance enhanced with IR imaging makes it easy
to spot intruders
24/7, without supplementary lighting.
| Intranet/Internet-enabled
system offers 32 user-defined IR regions of interest
per camera to trigger screen alarms or outputs
to SCADA systems |
"The declining cost of IR imaging technology now makes it economical to
provide both security and maintenance monitoring in a single package, on one
line, to any computer," said Jon Chynoweth, Vice President of Sales of Mikron
Infrared. "From a security standpoint, an intruder cannot hide from the
IR camera at night. And each IR camera effectively does 32 jobs by monitoring
that many user-defined zones, whether it be a fence perimeter for security or
a transformer for impending failure, triggering alarms at the master control
when high/low setpoints are exceeded. Up to 14 cameras can be monitored at one
time from a PC, and this system can easily be used as a component for an enterprise-wide
SCADA system."
The DualVision 724
system consists of separate thermal imaging and video
cameras in an environmentally sealed, temperature-controlled enclosure.
Both cameras
have Internet IP addresses and password protection, allowing control from
any computer using wired or wireless Ethernet.
MikroSpec Real-Time
Thermal Data Acquisition and Analysis software blends
the thermal and IR camera feeds into a single DualVision image with correct
aspect
ratio and spatial area. By applying an isotherm color pallet to the IR
image, hot spots are easily identified while viewing the scene as a visual
image.
The composite image can be adjusted to show any percentage of the IR
and visual. ROI's in the image can be defined using
10 different shapes, including
freehand.

The
MikroSpec R/T software can record up to 75 minutes
of blended visual
and IR video to a hard drive when capturing every frame from a camera
set at a
frame rate of 30 Hz. Total record time can be greatly extended by
capturing images
at intervals, rather than continuously. Video capture can be triggered
by a temperature alarm from one of the ROI's or by direct signal
from the PC.
A
user-selectable
prebuffer of video allows the operator to also capture what happened
in a scene before an event trigger. The IR and visual
cameras are housed in a single enclosure that has a
hinged back section containing all the interface connections,
including
RJ45 Ethernet,
RS170 video, connection for a high-resolution LCD, and a power termination
strip. The front section holds the cameras and has a slanted IR-transparent
window to
resist snow/dirt buildup. Cameras are supported on an internal shelf,
with space underneath for power supplies, wiring, etc. A remote-controlled
pan-and-tilt
head is also available.
The visual camera
can be color or b/w. Cameras can be fixed focus or
have auto iris and remote focus. The MikroScan IR camera
uses
state-of-the-art
uncooled
UFPA microbolometer technology, providing measurement accuracy
of ±2%
or 2°C. It can be set manually or automatically for three different
temperature ranges. Two image update rates (30Hz/60Hz) are selectable. Standard field of view is 28.9°(H) x 21.9°(V),
with autofocus from 30 cm to infinity. Telephoto and wide angle
lenses are available.
All DualVision systems
are fully integrated by Mikron Infrared
and provided on a turnkey basis to ensure customer satisfaction.
For More Information:
|
Jon Chynoweth
Mikron
|
888-506-3900
Send email to Jon Chynoweth
Visit the Mikron web
site. |
|